Features
- 3 1/2 digits large LCD display (18mm)
- Low battery indication & Auto power off
- Audible continuity
- Overload protection
- Frequency measurement
- Capacitance Measurement
- Temperature Measurement
- Auto power off if unused after 15 minutes
Specifications
Note: The following values can differ slightly from model to model; please consult your user manual for technical specifications.
DC Volts
Input impedance: 10MΩ
Range | Resolution | Accuracy |
---|---|---|
200mV | 0.1mV | ± 0.5% of rdg ± -1 digit |
2V | 1mV | ± 0.5% of rdg ± 1 digit |
20V | 10mV | ± 0.5% of rdg ± 1 digit |
200V | 100mV | ± 0.5% of rdg ± 1 digit |
1000V | 1V | ± 0.8% of rdg ± 2 digits |
AC Volts
Input impedance: 10MΩ at all ranges.
Frequency Response: 40Hz - 200Hz (40Hz-100Hz for the 200V and 700V range).
Overload Protection:
- 200mV: max. 15 seconds at a voltage of 300V AC
- all other ranges: 750V AC or 1000V DC.
Range | Resolution | Accuracy |
---|---|---|
200 mV | 0.1mV | ± 1.2% of rdg ± 3 digits |
2V | 1 mV | ± 0.8% of rdg ± 3 digits |
20V | 10 mV | ± 0.8% of rdg ± 3 digits |
200V | 100 mV | ± 0.8% of rdg ± 3 digits |
700V | 1V | ± 1.2% of rdg ± 3 digits |
DC Amps
Overload protection: 0.2A / 250V fuse
The 20A range is unfused. Maximum input current: 20 A for 15 seconds.
Range | Resolution | Accuracy |
---|---|---|
2mA | 1µA | ± 0.8% of rdg ± 1 digit |
20mA | 10µA | ± 0.8% of rdg ± 1 digit |
200mA | 100µA | ±1.2% of rdg ± 1 digit |
20A | 10mA | ± 2.0% of rdg ± 5 digits |
AC Amps
Overload protection: 0.2A / 250V fuse
The 20A range is unfused. Maximum input current: 20 A for 15 seconds.
Range | Resolution | Accuracy |
---|---|---|
200mA | 100µA | ± 2.0% of rdg ± 3 digits |
20A | 10mA | ± 3.0% of rdg ± 7 digits |
Note: some models have a 20mA range with a resolution of 10 µA and ±1,2% ± 3 digits accuracy.
Resistance (Ohms)
Range | Resolution | Accuracy |
---|---|---|
200Ω | 0,1Ω | ± 0.8% of rdg ± 3 digits |
2kΩ | 1Ω | ± 0.8% of rdg ± 1 digits |
20 kΩ | 10Ω | ± 0.8% of rdg ± 1 digits |
200 kΩ | 100Ω | ± 0.8% of rdg ± 1 digits |
2MΩ | 1kΩ | ± 0.8% of rdg ± 1 digits |
20MΩ | 10kΩ | ± 1% of rdg ± 2 digits |
200MΩ (a few models only) | 100 kΩ | ± 5% of rdg ± 10 digits |
Capacitance
Range | Resolution | Accuracy |
---|---|---|
2000pF | 1pF | ± 2.5% of rdg ± 5 digits |
20nF | 10pF | ± 2.5% of rdg ± 5 digits |
200nF | 100pF | ± 2.5% of rdg ± 5 digits |
2µF | 1nF | ± 2.5% of rdg ± 5 digits |
20µF | 10nF | ± 2.5% of rdg ± 5 digits |
Frequency
Range | Resolution | Accuracy |
---|---|---|
20kHz | 10Hz | ± 1% of rdg ± 1 digits |
Transistor hFE test
hFE range:0-1000
Ib: ~10µA
Uce: ~ 2,8V.
Temperature
"K" type thermocouple
Range | Resolution | Accuracy |
---|---|---|
-50°C - 400°C | 1°C | ± 0.75% of rdg ± 3 digits |
400°C-1000°C | 1°C | ± 1.5% of rdg ± 15 digits |
Diode and conductivity test
Diode test forward current: ~ 1mA.
Voltage: ~ 2.8V
The built-in buzzer will sound, if the resistance under test is less than about 30 ohms.