• Digital Multimeter - M890G - Capacitance Amp Volt Freq Temp. (VAR Tech) [Original]
  • Free Shipping on all Orders over Rs.999!!
  •  
  • Cash On Delivery [COD] only for order above Rs.5000/-

Digital Multimeter - M890G - Capacitance Amp Volt Freq Temp. (VAR Tech) [Original]

  • Product Code: TAM_M890G_VT
  • Availability: Out Of Stock
  • ₹1,439.83
  • ₹1,405.93 (+ GST)


Out of Stock
  • Shipping Charges Start from Rs.49*
  • Fast Order Processing <24hr
  • Shipment using reputed courier with 90% delivery in 1 - 3 working days
  • All order with GST invoice (B2B: 100% cliam GST credit input tax)

Digital Multimeter - M890G (VAR Tech - Orginal) - High quality

Features

  • 3 1/2 digits large LCD display (18mm)  
  • Low battery indication & Auto power off 
  • Audible continuity 
  • Overload protection 
  • Frequency measurement 
  • Capacitance Measurement
  • Temperature Measurement
  • Auto power off if unused after 15 minutes

Specifications

Note: The following values can differ slightly from model to model; please consult your user manual for technical specifications.

DC Volts

Input impedance: 10MΩ

Range Resolution Accuracy
200mV 0.1mV ± 0.5% of rdg ± -1 digit
2V 1mV ± 0.5% of rdg ± 1 digit
20V 10mV ± 0.5% of rdg ± 1 digit
200V 100mV ± 0.5% of rdg ± 1 digit
1000V 1V ± 0.8% of rdg ± 2 digits

AC Volts

Input impedance: 10MΩ at all ranges.
Frequency Response: 40Hz - 200Hz (40Hz-100Hz for the 200V and 700V range).
Overload Protection: 
- 200mV: max. 15 seconds at a voltage of 300V AC 
- all other ranges: 750V AC or 1000V DC.

Range Resolution Accuracy
200 mV 0.1mV ± 1.2% of rdg ± 3 digits
2V 1 mV ± 0.8% of rdg ± 3 digits
20V 10 mV ± 0.8% of rdg ± 3 digits
200V 100 mV ± 0.8% of rdg ± 3 digits
700V 1V ± 1.2% of rdg ± 3 digits

DC Amps

Overload protection: 0.2A / 250V fuse 
The 20A range is unfused. Maximum input current: 20 A for 15 seconds.

Range Resolution Accuracy
2mA 1µA ± 0.8% of rdg ± 1 digit
20mA 10µA ± 0.8% of rdg ± 1 digit
200mA 100µA ±1.2% of rdg ± 1 digit
20A 10mA ± 2.0% of rdg ± 5 digits

AC Amps

Overload protection: 0.2A / 250V fuse 
The 20A range is unfused. Maximum input current: 20 A for 15 seconds.

Range Resolution Accuracy
200mA 100µA ± 2.0% of rdg ± 3 digits
20A 10mA ± 3.0% of rdg ± 7 digits

Note: some models have a 20mA range with a resolution of 10 µA and ±1,2% ± 3 digits accuracy.

Resistance (Ohms)

Range Resolution Accuracy
200Ω 0,1Ω ± 0.8% of rdg ± 3 digits
2kΩ ± 0.8% of rdg ± 1 digits
20 kΩ 10Ω ± 0.8% of rdg ± 1 digits
200 kΩ 100Ω ± 0.8% of rdg ± 1 digits
2MΩ 1kΩ ± 0.8% of rdg ± 1 digits
20MΩ 10kΩ ± 1% of rdg ± 2 digits
200MΩ (a few models only) 100 kΩ ± 5% of rdg ± 10 digits

Capacitance

Range Resolution Accuracy
2000pF 1pF ± 2.5% of rdg ± 5 digits
20nF 10pF ± 2.5% of rdg ± 5 digits
200nF 100pF ± 2.5% of rdg ± 5 digits
2µF 1nF ± 2.5% of rdg ± 5 digits
20µF 10nF ± 2.5% of rdg ± 5 digits

Frequency

Range Resolution Accuracy
20kHz 10Hz ± 1% of rdg ± 1 digits

Transistor hFE test

hFE range:0-1000
Ib: ~10µA
Uce: ~ 2,8V.

Temperature

"K" type thermocouple

Range Resolution Accuracy
-50°C - 400°C 1°C ± 0.75% of rdg ± 3 digits
400°C-1000°C 1°C ± 1.5% of rdg ± 15 digits

Diode and conductivity test

Diode test forward current: ~ 1mA.
Voltage: ~ 2.8V 
The built-in buzzer will sound, if the resistance under test is less than about 30 ohms.

* Image shown is a representation only.


Note: Contact sales(at)electroncomponents.com for bulk enquiry & get best price!

Write a review

Please login or register to review